33
OPERATING PROCEDURES
11. Put on all personal protective gear.
12. Lay sprayer on its side to fill the pesticide tank (we
recommend the use of a funnel with at least 60
mesh screen to fill tank). Fill the insecticide tank to
within 1/2" of the top. When replacing the tank
cap, be sure that the O-ring is in place.
13. Restart the engine, and then depress the throttle
level (pull up) to full rpm's. Open the control valve
to start the flow of insecticide. The engine should
always be running at its fastest speed when
discharging insecticide.
TERMINATING PROCEDURES
14. ALWAYS close the control valve first! This stops
the flow of insecticide.
15. Release the throttle to reduce the engine RPM to
idle. NOTE: It is ABSOLUTELY NECESSARY to
close the control valve before reducing the engine
speed. If the control valve is left open with the
engine idling, the insecticide will not be atomized
and will drip from the nozzle.
CALIBRATION
16. Fill the insecticide tank with a known measure of
insecticide.