21. Remove the pick up tube from the formulation tank.
22. Disconnect the white nylon nut and fluid line from
the nylon elbow fitting attached to the filter/orifice
chamber Use two
13
/
16
” wrenches (one to hold the
tank fitting and the other to unscrew filter/orifice
chamber nut). Remove the orifice disc and filter
screen and install in the calibration pickup tube
assembly (supplied with the machine). Place an
orifice disc in line #39, 4 oz minute.
23. With the machine running, Run for one full minute
and note the amount of fluid used. It should be 4 oz.
Repeat for a second test. Try the other orifices #14,
1 oz/min, #22, 2 oz/min, #29, 3 oz/min and #51 6
oz/min.
APPLICATION
24. Read and understand and follow PESTICIDE label
instructions.
25. Use only pesticides that are labeled for your specific
application
26. Always use protective clothing and a respirator that
matches the pesticide and particle size being
applied.
27. Do NOT release the pesticide formulation flow until
the proper air pressure (60-90 psi) is reached.