DOD SR400D Especificaciones Pagina 228

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 244
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 227
220
TERMINATING PROCEDURES
 14. Turn off the pump switch and allow the remaining
pesticide in the sleeve to be expelled.
 15. Cut off the SL/BL and then the master switch.
 16. IN AN EMERGENCY, THE SPRAY OPERATION
CAN BE STOPPED IMMEDIATELY BY
TURNING OFF THE MASTER SWITCH FIRST.
 17. Flush the system by turning on the flush switch
on the control panel and run the system for at
least one minute.
 18. Turn off the flush switch and wipe the spray head
motor shaft with some additional flushing
solution. To do this, first apply the solution to a
cloth and then spray a small amount of lubricant
(such as WD-40) on the shaft.
 19. Remove the pesticide line from the container and
then secure the container.
 20. Store the unit in a dry area.
Vista de pagina 227
1 2 ... 223 224 225 226 227 228 229 230 231 232 233 ... 243 244

Comentarios a estos manuales

Sin comentarios