111
PERFORMANCE CHECKLIST FOR THE
JOHN BEAN PLC MODEL DP05E/30 PRB
HYDRAULIC SPRAYER
SETUP PROCEDURES
1. Check the entire sprayer thoroughly for any wear
areas, loose parts, and any items, which could
cause problems during operation.
2. Check oil level in engine, pump, and gearbox. Fill
all three with 30W oil as needed. Fill engine fuel
tank (regular unleaded).
3. Inspect the tank, filler basket, and suction strainer
for foreign materials. Clean or repair as necessary.
4. Inspect all hose and piping connections for loose
connections or damage. Repair as necessary.
5. Check spray gun nozzle disc size for required flow
rate at selected pressure (Check the "pesticide
label" for required flow rate).
6. Put on all personal protective gear.
7. Fill the tank with half the diluent needed, calculate
the amount of pesticide required and add to the
tank. Then add the remainder of the diluent.
8. Secure the pesticide tank cover.
Comentarios a estos manuales