146
30. The rate of vehicle speed during the spray
operation is generally 5 or 10 mph. The correct
speed for each type of pesticide is indicated on the
pesticide label.
31. When stopping for a short period of time, turn the
remote control output switch to the OFF position.
TERMINATING PROCEDURES
32. After completing your spray operation, with the
engine still running, turn the formulation selector
valve, located below the flushing solution tank, to
the "FLUSH" position.
33. Place the switch on the remote control in the
"FLUSH" position.
34. Place the output switch on the remote control in
the "ON" position.
35. Set the flow rate on the remote control digital read-
out to 10 oz/min and flush system for 2-3 min.
36. Turn all switches to the "OFF" position (Ignition,
formulation valve, and remote control switches).
CALIBRATION PROCEDURES
37. For ULV calibration, carry out steps 1-22.
38. Move the formulation selector valve, located below
the solution tank, to the "SPRAY" position.