 d. For a cold engine, on the Remote Station,
depress the choke button and starter button at
the same time, until the engine fires. Do not push
buttons for more than a maximum of 15
seconds/minute. CAUTION: HEARING
PROTECTION REQUIRED.
 e. For a hot engine, depress the starter button until
the engine fires.
 f. When the engine fires release the choke and
starter buttons (Note: Pressing the starter button
on the engine will also start the engine. The
main power switch on the Remote Control Station
must be in the “ON” position for the engine to be
started).
HOUR METERS
 17. The hour meter (on the Fog Generator) mounted
above the pressure gauge between engine and
blower records the engine-blower RPM when the
engine is running and the total engine-blower run
time for service/maintenance and security when the
engine is not running.
 18. The hour meter mounted on the Remote Control
Station records the time the ULV spray nozzle is
turned on.