28. When there are to be longer delays in operations,
FIRST turn off the pump and then switch the
throttle control on the instrument panel down to
"IDLE".
TERMINATING PROCEDURES
29. After completing your spray operation, turn the 4-
way valve on the control module to "FLUSHING".
30. Resume operations at full engine speed and reset
the "LED" readout to 10-ounces/minute, flow rate.
Run the machine for a minimum of 2 minutes.
31. Turn the pump switch, on the instrument panel to
"Off".
32. Run the engine at "IDLE" for 5 minutes for every
hour of actual spraying time. This helps to prevent
damage to the engine.
33. Close only the gasoline valve located at the
carburetor and let the engine run on "IDLE" until it
runs out of gas.
34. Turn the throttle control switch on the instrument
panel from "IDLE" to "OFF".