STARTING PROCEDURES
 17. Set the throttle switch on the instrument panel to
the "IDLE" position and flip the toggle switch,
located on the right side of the engine, to the "ON"
position. If engine fails to start, ensure sparkplug
gap is .030 thousandths of an inch. Spark plug
should be resistor type, Briggs & Straton Part#
802592 or champion spark plug RJ19LM.
 18. Turn engine switch, located on top of the engine,
to the "ON" position. Push the starter button,
located on the instrument panel, for a maximum of
30 seconds, or until the engine starts. CAUTION:
HEARING PROTECTION REQUIRED.
 19. As the engine warms up, slowly open the choke.
 20. Set the toggle switch into the "THROTTLE"
position.
Operating Procedures:
 21. Turn the 4way valve on the control module to the
"INSECTICIDE" position.
 22. Check the blower pressure gauge. If the gauge
does not read between 4.5 and 6.0 psi, then adjust
the engine speed by turning the silver throttle set
screw located on the carburetor.
 23. YOU ARE NOW READY FOR A ULV
APPLICATION.