28. Close the chemical control valve to stop the flow of
pesticide (toggle switch or manual valve).
29. Let engine run until all chemicals are expelled from
the nozzle (30 seconds).
30. Use the STOP switch at the throttle control on
engine below the air filter to stop the engine.
31. Always flush out entire system through the nozzle.
IAW manual, use soap and water, and dry the inside
of the tank with rags, - or air dry.
PREVENTIVE MAINTENANCE
32. Daily (or Before Every Use)
a. Air pump - Check oil level daily. Oil level must be
to the top mark on the dipstick. Use only London
Fog Anderol 500 or Amsoil Synthetic
Reciprocating Compressor Oil. Do not use
petroleum oil.
b. Engine - Check oil level. Oil level must be to the
top of the fill hole. Pay particular attention to the
engine requirement to change the oil after the
initial five hours of running time.
c. Belt- Check drive belts which should be in perfect
alignment and neither excessively tight or loose
enough to slip.