115
7. Grease the agitator shaft fitting located at the
agitator shaft flange at the rear of spray tank behind
the pulleys. Use multi-purpose lithium based grease
in a hand-operated gun.
8. Unscrew and examine the in-line jar-type filter and
clean as needed. The filter housing is located on the
right side of the pump.
9. Ensure that in-line valves located at the base of the
pump and on the right front part of the tank are in
the OFF position (handle is in cross-line position).
10. Ensure that the pressure relief valve, located
adjacent to the pump dome, is backed out with the
handle up.
11. Close the choke by moving the choke lever over to
the CHOKE CLOSE position (Omit this step if the
engine is already warm).
12. On a cold engine: place the throttle control midway
between the slow and fast positions.
13. Pull the starter rope firmly until the engine starts.
CAUTION: HEARING PROTECTION REQUIRED.
Return the rope in one smooth motion; DO NOT
LET GO OF THE ROPE!
14. As the engine warms up, slowly open the choke.
15. Put on all personal protective equipment (PPE).